<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Building Wire &#8211; Aluminium conductor,ABC Cable,XLPE Cable,PVC Cable,Power Cable,Overhead Cable</title>
	<atom:link href="https://www.jytopcable.com/products/building-wire/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.jytopcable.com</link>
	<description>JYTOP cable from China manufacturer,Factory Price!</description>
	<lastBuildDate>Tue, 26 Oct 2021 13:50:33 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=5.8.10</generator>
	<item>
		<title>XHHW-2 Conductor</title>
		<link>https://www.jytopcable.com/xhhw-2-conductor/</link>
					<comments>https://www.jytopcable.com/xhhw-2-conductor/#respond</comments>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Wed, 29 Sep 2021 05:41:49 +0000</pubDate>
				<category><![CDATA[Building Wire]]></category>
		<guid isPermaLink="false">http://www.jytopcable.com/xhhw-2-conductor/</guid>

					<description><![CDATA[Application: XHHW-2 cables are primarily use for power distribution. XHHW-2 cables may be used in wet or dry locations, with ambient temperatures not exceeding 90&#176;C. Voltage rating for RW90 cable is 600V. Conductors: &#160;1)&#160;XHHW-2 conductor is a compact soft drawn bare 8000 series aluminum, with Class B stranding per ASTM. &#160; &#160; &#160; &#160; &#160; [&#8230;]]]></description>
										<content:encoded><![CDATA[<p>
<strong>Application:</strong></p>
<p>
XHHW-2 cables are primarily use for power distribution. XHHW-2 cables may be used in wet or dry locations, with ambient temperatures not exceeding 90&deg;C. Voltage rating for RW90 cable is 600V.</p>
<p>
<strong>Conductors: &nbsp;1)&nbsp;</strong>XHHW-2 conductor is a compact soft drawn bare 8000 series <strong>aluminum</strong>, with Class B stranding per ASTM.<br />
&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;<strong>2)</strong> XHHW-2 conductor is a compact soft drawn bare <strong>copper</strong> with class B stranding per ASTM.</p>
<p>
<strong>Insulation: </strong>XHHW-2 has abrasion, heat and moisture resistant cross-linked polyethylene insulation XLPE, low coefficient of friction, &ldquo;slippery&rdquo; or &ldquo;slick&rdquo; material.</p>
<p>
<strong>Striping:&nbsp;</strong>XHHW-2 <a href="/overhead-insulated-cable/">Aluminium Conductor</a> is available with a &frac14;&rdquo; stripe with colors of your choice.</p>
<p>
<strong>Standards:</strong> XHHW-2 meets or exceed the following standards: UL standard 44 Requirements of the National Electrical Code ASTM standards B 800, B 801 Federal Specification J&ndash;C-30B Sunlight resistant.</p>
<p>&nbsp;</p>
<p>
&nbsp;</p>
<p> Aluminium XHHW-2 600V XLPE Insulated cables,XHHW-2 Conductor specifications(data sheet,table,full form) </p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.jytopcable.com/xhhw-2-conductor/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>USE-2/RHH/RHW-2 Wire cable</title>
		<link>https://www.jytopcable.com/use-2-rhh-rhw-2-wire-cable/</link>
					<comments>https://www.jytopcable.com/use-2-rhh-rhw-2-wire-cable/#respond</comments>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Wed, 29 Sep 2021 05:41:48 +0000</pubDate>
				<category><![CDATA[Building Wire]]></category>
		<guid isPermaLink="false">http://www.jytopcable.com/use-2-rhh-rhw-2-wire-cable/</guid>

					<description><![CDATA[Construction: USE-2, RHH, RHW-2 aluminum conductors are insulated cables that consist of compact stranded Aluminum alloy. aluminum alloy provides excellent conductivity while adding strength and resistance to corrosion for a long-lasting product. The USE-2 cable. RHH cable. RHW-2 cable for Direct Burial wire 600 Volts meets UL standard 854 for USE-2 conductors. This standard requires [&#8230;]]]></description>
										<content:encoded><![CDATA[<p>
<strong>Construction:</strong></p>
<p>
<a href="/building-wire/USE-2-RHH-RHW-2-Wire-cable.html">USE-2</a>, <a href="/building-wire/USE-2-RHH-RHW-2-Wire-cable.html">RHH</a>, <a href="/building-wire/USE-2-RHH-RHW-2-Wire-cable.html">RHW-2</a> aluminum conductors are insulated cables that consist of compact stranded Aluminum alloy. aluminum alloy provides excellent conductivity while adding strength and resistance to corrosion for a long-lasting product. The <a href="/building-wire/USE-2-RHH-RHW-2-Wire-cable.html">USE-2 cable</a>. <a href="/building-wire/USE-2-RHH-RHW-2-Wire-cable.html">RHH cable</a>. <a href="/building-wire/USE-2-RHH-RHW-2-Wire-cable.html">RHW-2 cable</a> for <a href="/building-wire/USE-2-RHH-RHW-2-Wire-cable.html">Direct Burial wire</a> 600 Volts meets UL standard 854 for USE-2 conductors. This standard requires the cable to be resistant to sunlight and work efficiently in high temperatures. The cable is able to function in temperatures up to 90&deg;C.</p>
<p>
<a href="/building-wire/USE-2-RHH-RHW-2-Wire-cable.html">USE-2 wire</a>, <a href="/building-wire/USE-2-RHH-RHW-2-Wire-cable.html">RHH wire</a>, and <a href="/building-wire/USE-2-RHH-RHW-2-Wire-cable.html">RHW-2 wire</a> &nbsp;are &nbsp;services entrance cable that can carry up to 600 volts. Service entrance cables distribute power &nbsp;from the service drop to an individual residence or building. The USE-2 RHH RHW-2 Direct Burial Aluminum Conductor 600 Volts is designed for underground use in direct burial applications, or within an electrical raceway, typically conduit. Conduit is a tube or trough that contains the electrical conductors, protecting them from corrosion, sunlight, and other interferences. Conduit comes in a variety of materials, shapes, and sizes. The best type of conduit will vary depending on the task at hand and the weather and climate conditions of the region where it is to be installed.</p>
<p>
<strong>Applications:</strong></p>
<p>
&bull; <a href="/building-wire/USE-2-RHH-RHW-2-Wire-cable.html">Kabel RHH</a> or RHW-2 or USE-2 conductors are used with conduit as specified in the NEC&reg; 2005 edition &bull; May also be used as underground service entrance cable, for direct burial, at conductor temperatures not to exceed 90&deg;C.<br />
&bull; When used as RHH, conductor temperatures shall not exceed 90&deg;C in dry locations.<br />
&bull; When used as RHW-2 or USE-2, conductor temperatures shall not exceed 90&deg;C in wet or dry locations.<br />
&bull; Voltage rating for RHH or RHW-2 or USE-2 conductors is 600 volts CONSTRUCTION DETAILS.<br />
&bull; RHH or RHW-2 or USE- 2 Type aluminum conductors are AA-8000 series aluminum alloy, compact stranded.<br />
&bull; Insulation is an abrasion, moisture, heat and sunlight resistant black cross-linked polyethylene (XLPE).</p>
<p> USE-2 RHH RHW-2 Direct Burial Aluminium Conductor 600V,USE-2/RHH/RHW-2 Wire cable specifications(data sheet,table,full form) </p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.jytopcable.com/use-2-rhh-rhw-2-wire-cable/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>6491X Single Core Solid or Stranded</title>
		<link>https://www.jytopcable.com/6491x-single-core-solid-or-stranded/</link>
					<comments>https://www.jytopcable.com/6491x-single-core-solid-or-stranded/#respond</comments>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Wed, 29 Sep 2021 05:41:47 +0000</pubDate>
				<category><![CDATA[Building Wire]]></category>
		<guid isPermaLink="false">http://www.jytopcable.com/6491x-single-core-solid-or-stranded/</guid>

					<description><![CDATA[Application: The building electric wire can be applied to the copper(aluminum)-core cables in the rated A/C voltage of 450/750V and the below power, lighting, daily electric appliances, apparatus and Telecommunication equipments. Particularly suitable for power circuits indoors or outdoors. Operation characteristics : 1. U0/U is 450/750V and 300/500V; 2.The allowed long-term working temperature of wire [&#8230;]]]></description>
										<content:encoded><![CDATA[<p>
<strong>Application:</strong></p>
<p>
The building <a href="/building-wire/">electric wire</a> can be applied to the copper(aluminum)-core cables in the rated A/C voltage of 450/750V and the below power, lighting, daily electric appliances, apparatus and Telecommunication equipments. Particularly suitable for power circuits indoors or outdoors.</p>
<p>
<strong>Operation characteristics :</strong><br />
1. U0/U is 450/750V and 300/500V;<br />
2.The allowed long-term working temperature of wire should not exceed 70&deg; C;The cable (wire) shall be installed at temperature not lower than 0&deg; C;<br />
3.The bending radius shall not be less than 4D of the cable overall diameter it is less 25mm; The bending radius shall not be less than 6D of cable overall diameter when it&rsquo;s more than 25mm.</p>
<p>
<strong>Construction:</strong></p>
<div style="overflow:auto"><table border="1" cellpadding="0" style="width: 70%">
<tbody>
<tr>
<td rowspan="2" style="width:135px">
<strong>Conductor</strong></td>
<td style="width:480px">
Solid Plain Copper Conductor</td>
</tr>
<tr>
<td style="width:480px">
Stranded Copper Conductor</td>
</tr>
<tr>
<td style="width:135px">
<strong>Insulation</strong></td>
<td style="width:480px">
PVC<br />
(Insulation color: &nbsp;Black, Brown, Yellow, Blue, Red, Green/Yellow, Grey, Orange, White is also available.)</td>
</tr>
</tbody>
</table></div>
<p></p>
<p> Copper Conductor PVC Insulated Electric Wiring Cable 450/750,6491X Single Core Solid or Stranded specifications(data sheet,table,full form) </p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.jytopcable.com/6491x-single-core-solid-or-stranded/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>THHN-THWN-THW-TW</title>
		<link>https://www.jytopcable.com/thhn-thwn-thw-tw/</link>
					<comments>https://www.jytopcable.com/thhn-thwn-thw-tw/#respond</comments>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Wed, 29 Sep 2021 05:41:47 +0000</pubDate>
				<category><![CDATA[Building Wire]]></category>
		<guid isPermaLink="false">http://www.jytopcable.com/thhn-thwn-thw-tw/</guid>

					<description><![CDATA[Applications: 1.Type THHN&#160;/&#160;THWN&#160;/ THW / TW Cable&#160;is intended for general purpose applications as defined by the National Electrical Code (NEC)Type THHN-THWN-2 is permitted for new construction or rewiring for 60 volt applications. Applications requiring Type THHN or THWN. a. THHN wire: It indicates a single or stranded conductor having flame-retardant and heat-resistant thermoplastic insulation with [&#8230;]]]></description>
										<content:encoded><![CDATA[<p>
<strong>Applications:</strong></p>
<p>
1.Type THHN&nbsp;/&nbsp;THWN&nbsp;/ THW / TW Cable&nbsp;is intended for general purpose applications as defined by the National Electrical Code (NEC)Type THHN-<strong><a href="/building-wire/THHN-THWN-THW-TW-Wire-Cable.html">THWN-2</a></strong> is permitted for new construction or rewiring for 60 volt applications. Applications requiring Type THHN or THWN.</p>
<p>
a. <strong><a href="/building-wire/THHN-THWN-THW-TW-Wire-Cable.html">THHN wire</a></strong>: It indicates a single or stranded conductor having flame-retardant and heat-resistant thermoplastic insulation with a jacket of extruded nylon or equivalent material. The wire is rated 90&deg;C dry only.THHN cable may also be used for wiring of machine tools, control circuits or on certain appliances.</p>
<p>
b. <strong><a href="/building-wire/THHN-THWN-THW-TW-Wire-Cable.html">THWN wire</a></strong>: It&nbsp;Indicates a single conductor having flame-retardant, moisture and heat-resistant thermoplastic insulation with a jacket of extruded nylon or equivalent material. The wire is rated 75&deg;C wet or dry. THWN cable is typically used for installation in conduit, machine tools, controlled circuits, or other general purpose wiring.</p>
<p>
c.<strong><a href="/building-wire/THHN-THWN-THW-TW-Wire-Cable.html">THW wire</a></strong>&ndash; Indicates a single conductor having flame-retardant, moisture and heat-resistant thermoplastic insulation. The wire is rated 75&deg;C wet or dry.THW cable and wires are used generally in building wiring, feeder and branch circuits, and internal secondary industrial distribution.</p>
<p>
d.<strong><a href="/building-wire/THHN-THWN-THW-TW-Wire-Cable.html">TW wire</a></strong>&ndash; Indicates a single conductor having flame-retardant, moisture-resistant thermoplastic insulation. The wire is rated 60&deg;C wet or dry.TW cable and wires are used generally in building wiring, feeder and branch circuits, and internal secondary industrial distribution.<br />
&nbsp;</p>
<p>
2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90&deg;C or not to exceed 75&deg;C in oil or coolants. Applications requiring Type MTW conductor is appropriate for use in dry locations at 90&deg;C, or not to exceed 60&deg;C in wet locations or where exposed to oils or coolants. Applications requiring Type AWM conductor is appropriate for use at temperatures to not exceed 105&deg;C in dry locations.</p>
<p>
<strong>Features:</strong><br />
1) Nylon outer jacket <a href="/building-wire/">PVC electric wire</a> for easy pulling. VW-1 rated 14 AWG &#8211; 8 AWG. All sizes are rated gasoline and oil-resistant II.<br />
2) Jacket: Nylon jacket is provided to protect PVC insulation against abrasions and scratches while pulling through conduits. It is also resistant to oil , gasoline and chemicals.</p>
<p>
<strong>Building Wire Construction:</strong><br />
Insulation: PVC (Poly Vinyl Chloride) with Secondary Nylon Jacket<br />
Conductor: Annealed solid or stranded copper wires (copper or CCA)<br />
Voltage Rating: 600 Volts.</p>
<p>
<strong>Standard:</strong><br />
THHN or&nbsp;THWN-2* or <a href="/building-wire/THHN-THWN-THW-TW-Wire-Cable.html">MTW wire</a> (also AWM) meets or exceeds all applicable ASTM specifications, UL Standard 83, UL Standard 1063 (MTW), Federal Specification A-A-59544, and requirements of the National Electrical Code.</p>
<p> Nylon Jacket PVC Building Electric Wire,THHN-THWN-THW-TW specifications(data sheet,table,full form) </p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.jytopcable.com/thhn-thwn-thw-tw/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>6181Y Single Core copper conductor</title>
		<link>https://www.jytopcable.com/6181y-single-core-copper-conductor/</link>
					<comments>https://www.jytopcable.com/6181y-single-core-copper-conductor/#respond</comments>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Wed, 29 Sep 2021 05:41:46 +0000</pubDate>
				<category><![CDATA[Building Wire]]></category>
		<guid isPermaLink="false">http://www.jytopcable.com/6181y-single-core-copper-conductor/</guid>

					<description><![CDATA[Description : 6491X PVC Insulated wire is a low voltage single core, PVC insulated copper conductor with an additional PVC oversheath for physical protection.Designed for use in light industrial and domestic wiring. These cables are particularly suited for installation as meter tails and are intended for fixed installation in dry or damp premises. Application: PVC [&#8230;]]]></description>
										<content:encoded><![CDATA[<p>
<strong>Description :</strong><br />
6491X <a href="/building-wire/6181Y-Single-Core-copper-pvc-cable.html">PVC Insulated wire</a> is a low voltage single core, PVC insulated copper conductor with an additional PVC oversheath for physical protection.Designed for use in light industrial and domestic wiring. These cables are particularly suited for installation as meter tails and are intended for fixed installation in dry or damp premises.</p>
<p>
<strong>Application:</strong><br />
<a href="/building-wire/">PVC electric wires</a> can be installed in conduit, in cable trunking and in cable ducting. Or where there is deemed little risk of mechanical damage these cables can be clipped direct, on cable tray, embedded or in free air. These cables are not intended to be laid underground.</p>
<p>
<strong>Construction:</strong><br />
1.Conductors: Solid or stranded plain annealed copper wire (class 1 or class 2) to BS, EN 60228.<br />
2.Insulation: PVC;<br />
3.Sheath: PVC;<br />
4.Voltage rating (U0/U) 300/500V;<br />
5.Max. Conductor temp 70&deg;C;<br />
6.Min, bending radius 4 x overall diameter of cable.</p>
<p> PVC Insulated PVC Sheathed Electric Wiring Cables (300/500V),6181Y Single Core copper conductor specifications(data sheet,table,full form) </p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.jytopcable.com/6181y-single-core-copper-conductor/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>6241Y,6242Y,6243Y</title>
		<link>https://www.jytopcable.com/6241y-6242y-6243y/</link>
					<comments>https://www.jytopcable.com/6241y-6242y-6243y/#respond</comments>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Wed, 29 Sep 2021 05:41:45 +0000</pubDate>
				<category><![CDATA[Building Wire]]></category>
		<guid isPermaLink="false">http://www.jytopcable.com/6241y6242y6243y/</guid>

					<description><![CDATA[Description : 6241Y, 6242Y, 6243Y flat earth wire cable available in sizes 1mm to 16mm and 1, 2 or 3 core. These PVC sheathed surface wiring cables, or Twin and Earth flat cables, which are generally used in domestic wiring of fixed installations. This British standard BS6004 cable is suitable to be fixed directly onto [&#8230;]]]></description>
										<content:encoded><![CDATA[<p>
<strong>Description :</strong></p>
<p>
6241Y, 6242Y, 6243Y flat earth wire cable available in sizes 1mm to 16mm and 1, 2 or 3 core. These PVC sheathed surface wiring cables, or Twin and Earth flat cables, which are generally used in domestic wiring of fixed installations. This British standard BS6004 cable is suitable to be fixed directly onto surfaces, ran through cable tray, Embedded or in free air,if there are no hazards from mechanical impact damage. These cables are not intended to be laid underground.</p>
<p>
<strong>Construction:</strong><br />
1.Conductor: Plain annealed copper solid (1.0 &#8211; 2.5mm&sup2;) or stranded (4.0 &#8211; 16.0mm&sup2;) circular conductor complying with BS EN 60228 Class 1 or Class 2.<br />
2.Insulation: PVC Insulation complying with BS EN 50363-3.<br />
3.Sheath: PVC sheath complying with BS7655.<br />
4.Circuit Protective Conductor. 300/500V.</p>
<p> PVC Insulated PVC Sheathed Flat Cable Twin and Earth Wire,6241Y,6242Y,6243Y specifications(data sheet,table,full form) </p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.jytopcable.com/6241y-6242y-6243y/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>PVC insulated copper wire</title>
		<link>https://www.jytopcable.com/multicore-pvc-insulated-copper-wire/</link>
					<comments>https://www.jytopcable.com/multicore-pvc-insulated-copper-wire/#respond</comments>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Wed, 29 Sep 2021 05:41:44 +0000</pubDate>
				<category><![CDATA[Building Wire]]></category>
		<guid isPermaLink="false">http://www.jytopcable.com/pvc-insulated-copper-wire/</guid>

					<description><![CDATA[Screened or Unscreended&#160;PVC insulated wire with copper conductor Multicore Industrial Electric wire Cables Description: Multicore cables are consist of multiple cores made up of wire. These types of wire are used in a high number of different applications including media/studio electronics such as camcorders and production equipment, security systems, as well as a wide variety [&#8230;]]]></description>
										<content:encoded><![CDATA[<p>
<strong>Screened or Unscreended&nbsp;<a href="/building-wire/">PVC insulated wire</a> with copper conductor Multicore Industrial <a href="/building-wire/">Electric wire Cables</a></strong></p>
<p>
<strong>Description:</strong><br />
Multicore cables are consist of multiple cores made up of wire. These types of wire are used in a high number of different applications including media/studio electronics such as camcorders and production equipment, security systems, as well as a wide variety of industrial and automation applications.</p>
<p>
<strong>Benefits:</strong><br />
1.to 40% smaller than comparable products<br />
2.Improved electrical, mechanical and thermal performance.<br />
3.Enhanced chemical and fluid resistance.<br />
4.Ultra-flexible cables and components available.<br />
5.Ability to include data, signal and power in the same cable.</p>
<p>
<strong>Features:</strong><br />
1.Cost savings over hand-built point-to-point harnesses<br />
2.Available in small order quantities<br />
3.Special testing available upon request<br />
4.Cable design services provided free-of-charge</p>
<p>
<strong>Applications:</strong><br />
1.Rotating turret<br />
2.Engine bay wiring<br />
3.Signal and power bulk wiring<br />
4.Back-up camera<br />
5.Weapon systems and radar<br />
6.Below deck zero halogen cabling<br />
7.Launch and contro systems<br />
8.Missile internal wiring<br />
9.Airframe communications systems</p>
<p> Multicore Industrial Electric wire Cables,PVC insulated copper wire specifications(data sheet,table,full form) </p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.jytopcable.com/multicore-pvc-insulated-copper-wire/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>2491X</title>
		<link>https://www.jytopcable.com/2491x-single-core-copper-conductor-pvc-insulated-flexible-cable/</link>
					<comments>https://www.jytopcable.com/2491x-single-core-copper-conductor-pvc-insulated-flexible-cable/#respond</comments>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Wed, 29 Sep 2021 05:41:44 +0000</pubDate>
				<category><![CDATA[Building Wire]]></category>
		<guid isPermaLink="false">http://www.jytopcable.com/2491x/</guid>

					<description><![CDATA[2491X (H05V-K / H07V-K) Cable Standards : BS6004:2000; Harmonised Type H05V-K (Sizes 0.5mm &#8211; 1.0mm) H07V-K (Sizes 1.5mm upwards) Application: 2491X cable is a Flexible PVC cable used for switch control in relay and instrumentation panels of power switchgear and is used for purposes such as internal connectors in rectifier equipment, motor starters and controllers. [&#8230;]]]></description>
										<content:encoded><![CDATA[<p>
<strong>2491X (H05V-K / H07V-K) Cable Standards :</strong></p>
<p>
BS6004:2000; Harmonised Type <a href="/CE-Certified-Cable/H05V-U-H05V-R-H05V-K.html">H05V-K</a> (Sizes 0.5mm &#8211; 1.0mm) <a href="/CE-Certified-Cable/H07V-U-H07V-R-H07V-K.html">H07V-K</a> (Sizes 1.5mm upwards)</p>
<p>
<strong>Application:</strong></p>
<p>
2491X cable is a Flexible <a href="/building-wire/">PVC cable</a> used for switch control in relay and instrumentation panels of power switchgear and is used for purposes such as internal connectors in rectifier equipment, motor starters and controllers.</p>
<p>
<strong>Construction:</strong></p>
<p>
Conductor: Flexible class 5 copper conductors to BS6360</p>
<p>
Insulation: PVC</p>
<p>
Temperature Rating: 70&deg;C</p>
<p>
Voltage Rating: <strong>H05V-K for 300V ac and 500V dc</strong>; <strong>H07V-K for 450V ac and 750V dc</strong></p>
<p>
Minimum Bending Radius : 6 x overall diameter.</p>
<p>
Colour : Black, Blue, Green/Yellow, Red, Yellow, White, Violet, Brown, Grey, Orange, Pink.</p>
<p>
Packaging &#8211; 100, 500, 1,000 metre reels. Barrels and other lengths available upon request.</p>
<p> Single Core Copper Conductor PVC Insulated Flexible Cable,2491X specifications(data sheet,table,full form) </p>
]]></content:encoded>
					